Parameter list for ND 281 B: "Linear measurement" mode of operation (factory default setting)
Parameter list
*
ND-281 B
MM
P01
MM =
P02
X1/X2 =
X1 11 uAPP =
P11
SCL =
SCALING OFF =
P12
SCL =
P17
CLASS. =
CLASS. OFF =
P18
L.CLASS. =
+
P19
U.CLASS. =
+
P21
SERIES =
DISPL.
P23
DISPL. =
DISPL. ACTL. =
P30
DIR =
DIRECT. POS =
P31
S. PER. =
P33
STEP =
COUNT 0-5 =
P38
DEC. =
P40
COMP. =
COMP. OFF =
P41
L.COMP. =
+
P42
BKLASH =
+
P43
REF =
SINGLE REF. =
P44
REF =
REF.
P45
ALARM =
FRQ.+ CONT. =
P50
RS232 =
9600 BAUD =
P51
RS232 =
BK LINE
P62
A1 =
+
P63
A2 =
+
P79
PRESET =
+
P80
ENT-CL =
CL-ENT OFF =
P82
DISPL.ON =
ENT..CL ON =
P85
EXT.REF =
EXT.REF OFF =
P86
MOD =
MOD START =
P98
LANGUA. =
LANGUAGE DE =
*
Description
Start character (*);
Model of display unit; MM or IN;
MM =
0
Unit of measure: MM = 0; INCH = 1;
0
Encoder input: X1 11µAPP = 0; X2 1VPP = 1;
0
SCALING OFF = 0; ON = 1;
1.000000
SCALING = 1.000000; (value input without sign)
0
Sorting: CLASS. OFF = 0; CLASS. ON = 1;
0.0000
Lower limit: L.CLASS = 0; (value input)
0.0000
Upper limit: U.CLASS = 0; (value input)
OFF =
0
SERIES: DISPL.OFF =0; MIN=1; MAX=2; ACTL=3; DIFF=4;
0
DISPLAY: ACTUAL = 0; HOLD = 1; STOP = 2;
0
COUNTING DIRECTION POS = 0; NEG = 1;
10
SIGNAL PERIOD = 10 µm; (value input without sign)
5
COUNTING MODE 0-5 = 5; 0-2 = 2; 0-1 = 1;
DP POS 4 =
4
DECIMAL PLACES 4 (range: 1-8)
0
COMPENSATION OFF = 0; LIN = 1; MULTI = 2;
0.0
LINEAR COMPENSATION= 0 µm/m (value input)
0.0000
BACKLASH compensation= 0.0000 mm (value input)
0
SINGLE REF. = 0; 500; 1000; 2000; 5000S P;
ON =
1
REF.ON = 1; REF. OFF = 0;
3
OFF = 0; FRQ. = 1; CONTAMINAT. = 2; FRQ + CONT. = 3;
9600
BAUD RATE = 9600; (110-38400)
1 =
1
LINE FEEDS = 1; (0-99)
0.0000
Switching limit 1: A1 = 0; (value input)
0.0000
Switching limit 2: A2 = 0; (value input)
0.0000
DATUM SETTING= 0; (value input)
0
CL-ENT OFF=0; CL-ON = 1; CL-ENT ON = 2;
1
DISPLAY: ENT...CL ON = 1; ENT...CL OFF = 0;
0
EXTERNAL REF OFF = 0; EXTERNAL REF ON= 1;
0
MOD key: START= 0; PRINT = 1; MIN = 2; ACTL = 3; MAX = 4; DIFF = 5;
1
NATIONAL LANGUAGE: 0 = EN; 1 = DE; 2 = FR; 3 = IT; 4 = NL; 5 = ES;
Final character(*);
6 = DA; 7 = SV; 8 = FI; 9 = CS; 10 = PL; 11= HU;
12 = PT;
55