Adjustments; Gas Burner Air Shutter - ALLIANCE 030 Series Installation Manual

Table of Contents

Advertisement

Adjustments

To reduce the risk of electric shock, fire, explosion,
serious injury or death:
Disconnect electric power to the tumble dryer be-
fore servicing.
Close gas shut-off valve to gas tumble dryer be-
fore servicing.
Close steam valve to steam tumble dryer before
servicing.
Never start the tumble dryer with any guards/
panels removed.
Whenever ground wires are removed during serv-
icing, these ground wires must be reconnected to
ensure that the tumble dryer is properly ground-
ed.

Gas Burner Air Shutter

NOTE: Air inlet shutters on the burner must be adjust-
ed so sufficient air is metered into the system for prop-
er combustion and maximum efficiency. Before adjust-
ing the inlet shutters be sure that all lint is removed
from lint compartments and lint screen.
Air shutter adjustments will vary from location to location and
will depend on the vent system, number of units installed, make-
up air and line gas pressure. Opening the shutter increases the
amount of primary air supplied to the burner while closing the
shutter decreases the primary air supply. Adjust air shutter as fol-
lows:
Refer to Figure 24 .
1. Remove the burner inspection hole plate.
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
Adjustments
WARNING
W002R1
2. Start the tumble dryer and check the flame pattern. If the
flame pattern is straight up, insufficient air is flowing through
the tumble dryer. A flame pattern that flares to the right and
left indicates no air is flowing through the tumble dryer. Cor-
rect air and gas mixture is indicated if the flame pattern is pri-
marily blue, with small yellow tips, and bends to the right of
the heater section. Too little air is indicated if the flame if yel-
low, lazy and smokey. (A whistling sound from burner could
also be caused by an improper air shutter setting.)
3. To adjust the air shutter, loosen air inlet shutter adjusting
screw.
4. Open or close air shutter as necessary to obtain proper flame
intensity.
5. After air shutter is adjusted for proper flame, tighten air shut-
ter adjusting screw securely.
80
Adjustments
TMB2411N_SVG
Figure 24
Part No. 70686701ENR4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

035 series055 seriesT30 seriesT45 seriesBa030eBt030n ... Show all