7-9-3. Platen too low sensor setting

The sensor is activated if it detects that the print medium is far because the platen is too low.
Enable or disable this function when using the printer.
(1)
From the menu, select [Printer Setting] > [Platen Setting] > [Platen too low sensor], and press
(2)
Select the "Platen too low" sensor function and press
<TIPS>
The "Platen too low" sensor checks if the platen is too low when it is completely inserted.
If the "Platen too low" sensor is activated, the printing process and the platen operation are stopped.

7-10. Print Operation Settings Under Low Temperature

Configure the printer with automatic switching to low temperature operation mode for ensuring print quality when [Temp
Low] is displayed on the liquid crystal panel. It is set to [Enable(Normal)], by default.
If the low temperature operation mode is enabled, the printer will automatically be switched to the low temperature
operation. Although it can assure print quality, it may take longer time for printing.
If the low temperature operation mode is disabled, print speed will not slow down; however, poor ejection may occur.
(1)
From the menu, select [Printer Setting] > [Low Temperature Mode], and press
(2)
Select the print mode under low temperature and press
<TIPS>
When [Disable] is selected, white ink injection may become unstable when trying to print a wide area.
Platen too low sensor
Enable
Disable
Low Temperature Mode
Enable (Normal)
Disable
7-8
.