B.13Time synchronization Status(Sync_Status)
Byte No.
Function
Register description:
1)00 represents synchronization success;
2)01 represents synchronization failure.
B.14 UTC Time(UTC_TIME)
Byte No.
byte1
Function
Byte No.
byte9
byte10
Function
us
Note: the range of us is from 0 to 999999.
B.15 Rotation Direction(ROTATION)
Byte No.
Function
Register description:
1)00 represents the motor rotates clockwise.
2)01 represents the motor rotates counterclockwise.
B.16 STATUS(STATUS)
Byte No.
byte1
Function
reserved
Byte No.
byte9
Function
Internal debug
Byte No.
17byte
Function
Internal debug
Note:[Value] is short type data (signed bit), in big endian mode.
Sync_Status(1 bytes in total)
UTC_TIME (10 bytes in total)
byte2
byte3
byte4
sec
ROTATION(1 bytes in total)
STATUS (18 bytes in total)
byte2
byte3
byte4
machine current
(Value)
byte10
byte11
byte12
Internal debug
18byte
19byte
20byte
Internal debug
39
1byte
Sync_Status
byte5
byte6
1byte
Rotation Direction
byte5
byte6
Idat2 reserved
byte13
byte14
Internal debug
21byte
22byte
Internal debug
RS-Ruby Plus User Manual
byte7
byte8
us
byte7
byte8
machine voltage
(Value)
byte15
byte16
Internal debug
23byte
24byte
Reserved
Need help?
Do you have a question about the LiDAR RS-Ruby Plus and is the answer not in the manual?
Questions and answers