Installation; Installation Requirements - Goodwe DNS Series User Manual

Grid-tied pv inverter 2.9-6kw
Hide thumbs Also See for DNS Series:
Table of Contents

Advertisement

User Manual V1.0-2022-12-15

5 Installation

5.1 Installation Requirements

Installation Environment Requirements
1. Do not install the equipment in a place near flammable, explosive, or corrosive materials.
2. Install the equipment on a surface that is solid enough to bear the inverter weight.
3. Install the equipment in a well-ventilated place to ensure good dissipation. Also, the
installation space should be large enough for operations.
4. The equipment with a high ingress protection rating can be installed indoors or outdoors.
The temperature and humidity at the installation site should be within the appropriate range.
5. Install the equipment in a sheltered place to avoid direct sunlight, rain, and snow. Build a
sunshade if it is needed.
6. Do not install the equipment in a place that is easy to touch, especially within children's reach.
High temperature exists when the equipment is working. Do not touch the surface to avoid
burning.
7. Install the equipment at a height that is convenient for operation and maintenance, electrical
connections, and checking indicators and labels.
8. The altitude to install the inverter shall be lower than the maximum working altitude
4000m(3000m for Australia).
9. The inverter is easy to be corroded when installed in salt areas. Please consult the inverter
manufacturer before installing it outdoors in salt areas. A salt area refers to the region
within 1000m offshore or affected by the sea breeze. The area prone to the sea breeze varies
depending on weather conditions (e.g. typhoon, monsoon) or terrain (such as dams and
hills).
10. Install the inverter away from high magnetic field to avoid electromagnetic interference.If
there is any radio or wireless communication equipment below 30MHz near the inverter, you
have to:
• Install the inverter at least 30m far away from the wireless equipment.
• Add a low pass EMI filter or a multi winding ferrite core to the DC input cable or AC output
cable of the inverter.
Children no touch
11
05 Installation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents