6.5.2 Connecting the Communication Cable (optional)

• Make sure that the communication device is connected to the right terminal. Route the
communication cable far away from any interference source or power cable to prevent the
signal from being influenced.
• Connect the CT cable using a 2PIN communication terminal.
• Connect the DRED cable, RS485 cable, and remote shutdown cable using a 6PIN
communication terminal.
• DRED (Demand response enabling device) is only for Australian and New Zealand
installations, incompliance with Australian and New Zealand safety requirements.
• Contat the after-sales service to get the DRED terminal if you need to use DRED function.
• DRED function is off by default. Start this function via SolarGo App if it's needed.
• Remote shutdown is only for Europe installations, in compliance with European safety
requirements. And Remote shutdown device is not provided by GOODWE.
• Remote shutdown function is off by default. Start this function via SolarGo App if it's
needed.
DRED/Remote Shutdown Communication Cable
• DRED: Australia
• Remote Shutdown: Europe
Notice
DRED
1: DRM1/5
2: DRM2/6
3: DRM3/7
4: DRM4/8
5: REFGEN
6: COM/DRM0
Remote
Shutdown
2: REFGEN
3: DRM4/8
23