06 Electrical Connection
• Make sure that the cable is connected correctly and securely. Clear the debris after completing
the connection.
• Seal the AC output terminal to ensure the ingress protection rating.

6.5 Communication

6.5.1 Communication Network Introduction

Power Limit Network
The PV station generates power for self-consumption, but the electric equipment cannot
consume all the generated power. The inverter can monitor the on-grid electric data in real-time
and adjust the output power via a smart meter to avoid the residual current feeding back to the
utility grid.
CT90
Inverter
PV String
After completing cable connections, set related parameters via LCD or SolarGo app to enable
export power limit control or output power limit control.
NOTICE
Circuit
Breaker
Loads