Goodwe DNS Series User Manual

Goodwe DNS Series User Manual

Solar inverter
Hide thumbs Also See for DNS Series:

Advertisement

SEMS Portal App
LinkedIn
Offical Website
GOODWE (Germany)
Fürstenrieder Str. 279a 81377 München, Germany
sales.de@goodwe.com
service.de@goodwe.com
GOODWE (Netherlands)
Franciscusdreef 42C, 3565AC Utrecht, the Netherlands
sales@goodwe.com
service.nl@goodwe.com
GOODWE (India)
1202, G-Square Business Park, Sector 30A, Opp. Sanpada
Railway Stn., Vashi, Navi Mumbai- 400703
sales@goodwe.com / service.in@goodwe.com
GOODWE (Turbutton)
Adalet Mah. Megapol Tower K: 9 No: 110 Bayraklı - Izmir
info@goodwe.com.tr
service@goodwe.com.tr
GOODWE (Mexico)
Oswaldo Sanchez Norte 3615, Col. Hidalgo, Monterrey,
Nuevo Leon, Mexico, C.P. 64290
sales@goodwe.com / soporte.latam@goodwe.com
Note: The information above is subject to change without prior notice, for details refer to
www.goodwe.com
GOODWE (China)
No. 90 Zijin Rd., New District, Suzhou, 215011, China
sales@goodwe.com (sales)
service@goodwe.com (service)
GOODWE (Brazil)
Rua Abelardo 45, Recife/PE, 52050-310
sergio@goodwe.com
servico.br@goodwe.com
GOODWE (UK)
6 Dunhams Court, Dunhams Lane, Letchworth
Garden City, SG6 1WB UK
enquiries@goodwe.com.uk / service@goodwe.com.uk
GOODWE (Italy)
Via Cesare Braico 61, 72100 Brindisi, Italy
valter.pische@goodwe.com (sales)
operazioni@topsenergy.com; goodwe@arsimp.it (service)
GOODWE (Australia)
Level 14, 380 St. Kilda Road, Melbourne,
Victoria, 3004, Australia
sales@goodwe.com / service.au@goodwe.com
GOODWE (Korea)
8F Invest Korea Plaza, 7 Heoleung-ro
Seocho-gu Seoul Korea (06792)
sales@goodwe.com / Larry.Kim@goodwe.com
DNS SERIES USER MANUAL
SOLAR INVERTER
Ver 1.1

Advertisement

Table of Contents
loading

Summary of Contents for Goodwe DNS Series

  • Page 1 SEMS Portal App LinkedIn Offical Website GOODWE (China) No. 90 Zijin Rd., New District, Suzhou, 215011, China sales@goodwe.com (sales) service@goodwe.com (service) DNS SERIES USER MANUAL GOODWE (Germany) GOODWE (Brazil) Fürstenrieder Str. 279a 81377 München, Germany Rua Abelardo 45, Recife/PE, 52050-310 sales.de@goodwe.com sergio@goodwe.com service.de@goodwe.com...
  • Page 2: Table Of Contents

    1 Symbols ..........................2 Safety Measures & Warning ............... 3 Product Introduction ..................3.1 Inverter Overview ........................04 3.2 Package ............................05 4 Installation ........................4.1 Mounting Instructions ....................... 05 4.2 Equipment Installation ......................06 4.3 Electrical Connection ........................ 07 4.4 Communication Connection ....................
  • Page 3: Symbols

    The DNS series inverter of Jiangsu GOODWE Power Supply Technology Co, Ltd. (hereinafter Failure to observe warnings indicated in this manual may result in referred to as GOODWE) strictly conforms to related safety rules in design and test. Safety regula- injury.
  • Page 4: Product Introduction

    Make sure that there is no risk of water or dust entering terminals / holes. GOODWE provides standard manufacture warranty to inverter products, which will be delivered with the product. We also provide prepaid warranty extension solution to our customer. You can find the details about the terms and solutions from official website: https://en.goodwe.com/war-...
  • Page 5: Package

    3.2 Package 4.2 Equipment Installation The units have been thoroughly tested and strictly inspected before delivery. Damage may still 4.2.1 Select Installation Location occur during shipping. 1. Check the package for any visible damage upon receiving. Please take the following points into consideration when you are selecting a proper location to 2.
  • Page 6: Electrical Connection

    Installation instruction of VACONN series Expansion Pipe 195mm Fasten the screw cap clockwise Wall-Mounting Bracket 10mm 115mm Material(Annealed copper wire) Fasten the screw cap clockwise Fastening three screws and Self-tapping Screws ensure each screw head is 130mm not exceeding the surface Installation instruction of WELAND series fasten the screw cap clockwise 10mm...
  • Page 7 Please follow the steps below to connect PE cable to ground. inverter. 3. Only DC connectors provided by GoodWe are permitted. Step 1 4. Do not connect the positive and negative pole to the PE cable (Ground cable). Otherwise, the Strip the wire insulation layer to a suitable length using a wire stripper.
  • Page 8: Communication Connection

    4.4 Communication Connection 4.4.1 USB Connection USB interface is used for after-sales service team to repair inverter only. Not allowed for any other AMPHENOL SERIES QC4.10 SERIES purposes. Step 1: Unscrew this plate from inverter. Note: The actual DC connector used is as shown in the accessory box. DC cable specification: Label Description...
  • Page 9 Please follow the steps below to complete RS485 communication connection. After configuration, please create PV station using the monitoring portal website. 4.4.4 Export Power Limit Connection Diagram Step 1: Unscrew this plate from the inverter. Connect the Power Limiting device CT shown below. white &...
  • Page 10 Note: Step 2-1 For DRED: 1. Compatible DRED commands are DRM0, DRM5, DRM6, DRM7, DRM8. Thread the cable through the connector and 2. Please set up power limit function at local setting page once all connection steps are done. connect to the terminal. 3.
  • Page 11: System Operation

    5 System Operation 5.2.2 Set Safety Country If the LCD displays "Configure Safety", then long press the button to enter the sub-menu. Short 5.1 LCD Panel And LED press to browse the available safety country. Select the suitable safety country according to the 5.1.1 Indicator Lights location of installation.
  • Page 12 Main Menu Sub Menu Check PV voltage, PV current, grid voltage, current and frequency: Normal Long Press 50Hz Grid Default Pac=2595.5W • Short press the button to enter the "E-Today" menu, which displays the total power generation Short Press E-Today=15.2KWh Long Press for today.
  • Page 13 • Set language default is OFF) and the power limiting setting (the default is 2% rated power): Long press the button to enter the password input menu. The initial display "1111" is the default password. Short press the button to enter "Set Language". Long press the button to enter the sub menu. Short press the button to increase the number in current position and long press to move to the Short press the button to browse the languages available.
  • Page 14: Error Message

    5.4 Wi-Fi Reset & Wi-Fi Reload the button to check the result. These functions are only available for Wi-Fi model inverters. Main Menu Sbu Menu Main Menu Long Press Wait Auto Test Normal Wi-Fi reload function is used to reconfigure the Wi-Fi to default. Please configure the Wi-Fi again Auto Testing Pac=XXXX.XW Pac=XXXX.XW...
  • Page 15: Special Adjustable Setpoints

    5.6 Special Adjustable Setpoints 5.6.2 PU Curve Mode The PU curve mode can be modified by Modbus communication method, specifically according The inverter has a field in which the user can set functions, such as trip points, trip times, recon - to the machine Modbus address and Modbus register value, according to the set range to set the nect times, active and inactive QU curves and PU curves.
  • Page 16: Troubleshooting

    6 Troubleshooting Fault Troubleshooting In most situations, the inverter requires very little maintenance. However, if the inverter is not Relay-Check Failure working properly, please try the following troubleshooting solutions: DCI Injection High • When a problem occurs, the red (fault) LED indicator on the front panel will light up and the 1.
  • Page 17: Technical Parameters

    7 Technical Parameters Technical Data GW3600T-DS GW4200T-DS GW5000T-DS GW6000T-DS GW5KBD-NS GW6KBD-NS PHB5000T-DS Technical Data GW2900D-NS GW3000D-NS GW3600D-NS GW4200D-NS GW5000D-NS GW6000D-NS GW3000T-DS Input Input Max.Input Power (W) 4680 5460 6500 7200 6500 7200 6500 Max.Input Power (W) 4000 3900 4680 5460 6500 7200 3900...
  • Page 18: Maintenance

    Note: 8 Maintenance Overvoltage Category Definition Regular maintenance ensures a long operating life and optimal efficiency of the entire PV plant. Category Ⅰ Applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low level Caution: Before maintenance, please disconnect the AC breaker, and disconnect DC breaker Applies to equipment not permanently connected to the installation.

Table of Contents