Technical Parameters - Goodwe DNS Series User Manual

Grid-tied pv inverter 2.9-6kw
Hide thumbs Also See for DNS Series:
Table of Contents

Advertisement

10 Technical Parameters

10 Technical Parameters
Technical Data
Input
Max. Input Power (W)
*1
Max. Input Voltage (V)
MPPT Operating Voltage
Range (V)
MPPT Voltage Range at
Nominal Power (V)
Start-up Voltage (V)
Nominal Input Voltage
(V)
Max. Input Current per
MPPT (A)
Max. Short Circuit
Current per MPPT (A)
Max. Backfeed Current
to The Array (A)
Number of MPPT
Number of Strings per
MPPT
Output
Nominal Output Power
(W)
*2*3
Nominal Output
Apparent Power (VA)
*4
Max. AC Active Power
(W)
Max. AC Apparent Power
(VA)
Nominal Power at 40℃
(W)(For Brazil only)
Max Power at 40℃
(Including AC Overload)
(W)(For Brazil only)
Nominal Output Voltage
(V)
Nominal AC Grid
Frequency (Hz)
Max. Output Current (A)
Nominal Output Current
(A)
Power Factor
Max. Total Harmonic
Distortion
GW2900D-NS
GW3000D-NS
4000
3900
535
600
80 - 435
80 - 550
N/A
150 - 550
80
80
230
360
12.5
11
15.6
13.8
0
0
2
2
1
1
2900
3000
2900
3000
2900
3000
2900
3000
2900
3000
2900
3000
127
220/230
60
50/60
22.9
13.6
22.9
13.6/13.0
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
<3%
User Manual V1.0-2022-12-15
GW3600D-NS
GW4200D-NS
4680
5460
600
600
80 - 550
80 - 550
180 - 550
210 - 550
80
80
360
360
11
11
13.8
13.8
0
0
2
2
1
1
3680
4200
3680
4200
3680
4200
3680
4200
3680
4200
3680
4200
220/230
220/230
50/60
50/60
16.0
19.0
16.0/15.6
19.0/18.2
<3%
<3%
36
GW5000D-NS
GW6000D-NS
6500
7200
600
600
80 - 550
80 - 550
240 - 550
280 - 550
80
80
360
360
11
11
13.8
13.8
0
0
2
2
1
1
5000
6000
5000
6000
5000
6000
5000
6000
5000
6000
5000
6000
220/230
220/230
50/60
50/60
22.8
27.3
22.8/21.7
27.3/26.1
<3%
<3%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents