Download Print this page

Specifications - Luna BTS 315 User Manual

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 46
Wear hearing protection systems.
Danger of electric shock. Do not access the
area when the machine is powered.
Carefully read and understand the manual
before using the machine.
Information signals:
Indicate the technical characteristics, direction of
rotation and inclination, block and release, etc.
Carefully following the directions to simply the use
and adjustment of the machine.
The signals are graphically described and do not
require further explanation.

3. SPECIFICATIONS

3.1 Main components
1 2
6
7
8
9
1. Right extension table
2. Main table
3. Blade guard assembly
4. Blade
5. Rear extension table
6. Sliding table
7. Telescopic fence
8. Square sliding table
9. Tilting handwheel
10. Lifting handwheel
11. Frame assembly
12. Rip fence assembly
13. Square sliding table
3.2 Technical specification
Art.No. ...................................................... 23674-0106
Luna ................................................................ BTS315
Motor Voltage ...................................... 3~400 V/50 Hz
Main motor power ........................................ 2.5 kW,S1
Scoring motor power ..................................... 550 W,S1
5
4
3
2
1
10
Main blade diameter ........................................315 mm
Main blade speed .......................................... 4000 rpm
Scoring blade diameter ....................................120 mm
Scoring blade speed ...................................... 8000 rpm
Blade tilt .............................................................. 0~45°
Main table size .......................................800 x 530 mm
Right extension table size ......................800 x 470 mm
Max.rip capacity ..............................................900 mm
Max.depth of cut ...............102 mm@90°,72 mm@45°
Sliding table size ..................................1200 x 360 mm
Sliding table stroke ........................................1200 mm
Square sliding table size .........................600 x 460 mm
3.3 Electrical connection
• Electrical installation should be carried out by com-
petent, qualified personnel.
• The mains connection should be made using the ter-
minal box.
• Replacement of the power supply cable should only
be done by a qualified electrician.
• Connect the main leads to a standard 400V±10% for
TS315 and 230V±10% for TS315 (50Hz+1%Hz)
electrical supply which has protection devices of
under-voltage, over-voltage, over-current as well as
a residual current device (RCD) which maximum
residual current rated at 0.03A, the main connection
must have maximum 20A time-lag fuse for TS315
and 10A for TS315. The test specified in 18.2 of EN
11
60204-1:2006 should be performed by end user after
final installation.
To avoid electrocution or fire, any maintenance or
repair to electrical system should be done only by
qualified electricians using genuine replacement parts.
L1
PE
1L1 1L2 1L3
1 0
Q1
2L1
2L2
KM2
U2 V2 W2
U1
M2
47
L2
L3
N
SB
SA
TR1
Q1
F1
12
13
14
15
2L3
11
KM1
V1 W1
M1
3~400 V/50 Hz 2.5 kW
S1
ST
A1 A2
16
17
18
KM1
KM1
S2
A1 A2
19
KM2
KM2