11.21 Door is open - cooking program was stopped
Description
Overview
Troubleshooting
Check that the "On/Off" switch functions properly and is in the
correct position.
The switch must be fastened securely.
The switch is available separately.
Check the electrical connections and screw connections in the
area of the mains connection terminal, transformer and power line
to the control board (connector X1).
Replace control board. It supplies voltage to the operating panel.
Replace transformer.
Replace operating panel.
During fault-free operation, this message appears if the cooking
chamber door is opened during an active cooking program. If the
message is displayed with a closed cooking chamber door, there is
an error on the reed contact switch or door magnet.
a
a Reed contact switch
The operating state of the reed contact switch can be checked in the
status overview.
1. Open cooking chamber door. Check reed contact switch operation
with external magnet.
The magnet is not detected. Check reed contact switch and
replace if necessary.
The magnet is detected. Check magnet in cooking chamber
door for correct position and replace if necessary.
Service-instructions
b
b Door magnet
Error messages