Henny Penny FlexFusion ELECTRIC SPACESSAVER Service Instructions Manual page 18

Table of Contents

Advertisement

Service menu - appliance test
18
Step 3 (heat output)
1. Check of heat output.
Display switches to green = test successful.
Display switches to red = test not successful.
Check of on-site voltage supply.
Check of heating element
Check of solid-state relay
Check of internal fuse for load circuit (depends on unit version).
Step 4 (steam generation)
1. Check of DynaSteam² steam generation.
Display switches to green = test successful.
Display switches to red = test not successful.
Ensure that water is being supplied on-site.
Check of DynaSteam² steaming unit.
Check of water supply pipe for calcification.
Step 5 (steam reduction)
1. Check of steam reduction (solenoid).
Display switches to green = test successful.
Display switches to red = test not successful.
Check of solenoid via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Step 6 (WaveClean circulation pump)
1. Check of WaveClean circulation pump.
Display switches to green = test successful.
Display switches to red = test not successful. Test 7 and 8 are
not evaluated.
Check of circulation pump via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Step 7 (water supply to WaveClean)
1. Check of solenoid valve for steam elimination.
Display switches to green = test successful.
Display switches to red = test not successful.
Ensure that water is being supplied on-site.
Check of solenoid valve via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Service-instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexfusion electric spacessaver plusFse-605Fse-610

Table of Contents