System Settings" Command; Fig. 6-21: Output Word 0 (Out[0]) System Settings; Fig. 6-22: Use Of The Parameters Within The System Settings Command Within The Individual Operating Modes - Bosch Rextroth Indramat RECO R-IB IL CNT Applications Manual

Inline counter terminal
Table of Contents

Advertisement

6-12
Commands used when working with the Counter Terminal
6.6

"System Settings" Command

15
14
13
12
0
0
1
1
This command makes various settings, some of which influence all
operating modes.
The command for the system settings comprises the command code and
various parameters.
Output word 0 (OUT[0])
11
10
9
8
0
0
EB

Fig. 6-21: Output word 0 (OUT[0]) System Settings

The second output word is not used.
Basic settings for all operating modes can be made using the system
settings command. However, the definition of the various parameters
depends on the operating mode. Not all parameters can be defined in
every operating mode.
Fig. 6-22, illustrates the use of the parameters within the system settings
command within the individual operating modes.
Parameter
EB input wiring
No input wiring (parameter EB =
00
)
bin
Filter for mechanical switch
(parameter EB = 01
Setting for the pulse generator
(parameter EB = 10
Source-gate link
(parameter EB = 11
Source-gate link
Bus-reset behavior
Pulse duration
Fig. 6-22: Use of the parameters within the System Settings command within the
individual operating modes.
Note:
Apart for the setting of the pulse duration, the system setting is
immediately accepted within an operating mode that is already
running.
7
6
5
4
Source-Gate Link
Used in Operating Mode:
All
Frequency measurement, event count,
time measurement
)
bin
Pulse generator
)
bin
Frequency measurement, event count,
time measurement
)
bin
Frequency measurement, event count,
time measurement
All
Event count
DOK-CONTRL-R-IL*CNT***-AW02-EN-P
Counter Terminal
3
2
1
0
Reset
Pulse Duration