7-6
Examples and Hints
Programming
System settings
S o u r c e
G a t e
O R
15
14
13
12
0
0
1
1
0
0
1
1
3
The commands for the system settings and for the basic conditions must
first be issued before issuing the command for the selection of the
operating mode.
The system settings command is used for linking the two limit switch
signals. The logical OR-link is selected (source' equals "1" if the source or
gate signal is at "1").
Fig. 7-8: OR-link of source and gate
Input wiring
Source-gate link
Source-Gate
OR
link
Reset
No reaction to a BUS reset.
Pulse
(Pulse duration 10 ms) irrelevant, as no
duration
output is to be set
11
10
9
8
0
0
EB
0
0
1
1
3
Fig. 7-9: Output word 0 (OUT[0]) system settings OR-link of source and gate
The command for the system settings is 33E0
7
6
5
4
Source-Gate link
1
1
1
0
E
hex
DOK-CONTRL-R-IL*CNT***-AW02-EN-P
Counter Terminal
5 9 7 9 0 0 1 3
59790013.eps
11
bin
1110
bin
0
bin
000
bin
3
2
1
0
Reset
Pulse duration
0
0
0
0
0
.