Performance Characteristics; System Overview - Bosch API-AMC2-4WE Installation Manual

Access modular controller 2
Hide thumbs Also See for API-AMC2-4WE:
Table of Contents

Advertisement

10
en | Introduction
3.3

Performance Characteristics

Notice!
If an external power supply is used, this should also guarantee an uninterruptable power
supply (UPS). Example: Bosch power supply APS-PSU-60 (F.01U.282.970).
3.4

System Overview

The AMC2-4WE is connected between the access controller AMC2-4W and the various
peripheral devices.
Figure 3.4: System overview
1 =
2 =
3 =
4 =
5 =
2020-01 | V02 |
Controlled by an AMC2 via RS-485
Reader interfaces
four two Wiegand interfaces
Eight relay outputs
voltage free, power is supplied externally (dry mode)
powered by internal power supply (wet mode)
Eight analog inputs with internal power supply
Transfer rate to the extension interface: 9,6 kBit/s
Self regulating transmit/receive switching
Power supply:
10V - 30Vdc - max. 3 A
or over the RS-485 host connector
Information about the inputs and outputs on the display of the AMC2 controller
Tamper contact for external covers
Host
AMC2-4W
Card reader
Communication and power supply
AMC2-4WE
Installation manual
Access Modular Controller 2