Fig. 6-18: Comparative Conditions - Bosch Rextroth Indramat RECO R-IB IL CNT Applications Manual

Inline counter terminal
Table of Contents

Advertisement

6-10
Commands used when working with the Counter Terminal
001:
Counter value is greater than or
equal to the starting value
OUT = 1
OUT = 0
X
003: Counter value is within the
starting value and final value
OUT = 1
OUT = 0
X
005: Counter value is greater than the
starting value with hysterisis
OUT = 1
OUT = 0
X
Hystereses:
Example 1
²
OUT = 1
OUT = 0
OUT = 1
OUT = 0
Y
OUT = 1
OUT = 0
Y

Fig. 6-18: Comparative conditions

Legend:
X
Start value
Y
End value
Limit value is included
Limit value is not included
The gray line of the hystereses makes clear the condition of OUT
depending on the previous condition of OUT and the measured value. If
the measured value, e.g. is between the start value and the end value for
curve 006 then OUT can either be equal to 0 or to 1. If OUT was = 0, then
OUT remains at 0; if OUT was = 1, then OUT remains at 1.
A hysteresis thereby provides the possibility of obtaining stable output
behavior for measured values that deviate within certain limit values.
The effect of a comparative condition is illustrated based on the condition
"004: counter value outside of the start value and end value".
• If the counter value is smaller than the start value then the
comparative condition is fulfilled and OUT is set to "1".
• If the counter value is greater than or equal to the start value and
smaller than/equal to the end value then the comparative condition is
not fulfilled and OUT is set to "0".
• If the counter value is greater than the end value then the comparative
condition is fulfilled and OUT is set to "1".
002: Counter value is less than
the starting value
X
004: Counter value is outside of the
starting value and final value
X
006: Counter value is less than the
starting value with hysterisis
X
DOK-CONTRL-R-IL*CNT***-AW02-EN-P
Counter Terminal
Y
Y
5979A012
5979a018.eps