Samsung CLX-9252 Series Service Manual page 334

A3 color copier
Hide thumbs Also See for CLX-9252 Series:
Table of Contents

Advertisement

● Code :
A3-3311
A3-3312
A3-3411
A3-3412
● Symptom / Cause :
Outer temperature/humidity sensor is defective.
● Troubleshooting method :
• A3–3311 / A3–3312 : Temperature function is abnorm
• A3–3411 / A3–3412 : Humidity function is abnormal.
1. Enter SVC mode. Execute sensor test to check the
(Diagnostics > Engine Diagnostics > Engine Tes
2. Remove the left cover.
Measure the resistance value of the connector at b
If the value is not in 47.5KΩ ~ 52.5KΩ (@ 25 ℃), re
3. If the harness and sensor are normal, replace the m
(JC92-02580A for 9352 / JC92-02581A for
Service Manual
7. Troubles
● Error message :
Sensor Failure: #A3-3311. Tu
Sensor Failure: #A3-3312. Tu
Sensor Failure: #A3-3411. Tu
Sensor Failure: #A3-3412. Tu
shooting
urn off then on. Call for service if the problem persists.
urn off then on. Call for service if the problem persists
urn off then on. Call for service if the problem persists
urn off then on. Call for service if the problem persists
mal.
sensor operation.
st Routines > 123-0060 Outer Temperature )
both ends.
eplace the sensor(JC32-00015A).
main board.
9252)
7-3
37
SAMSUNG ELECTRONICS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-9352 series

Table of Contents