Rotate The Transmitter On The Sensor (Optional) - Emerson MicroMotion FOUNDATION 5700 Installation Manual

Table of Contents

Advertisement

Installation Manual
MMI-20029969
3.5

Rotate the transmitter on the sensor (optional)

In integral installations, you can rotate the transmitter on the sensor up to 360° in 45°
increments.
Procedure
1. Using a 4 mm hex key, loosen and remove the clamp securing the transmitter head
2. Gently lift the transmitter straight up, and rotate the transmitter to the desired
3. Gently lower the transmitter onto the base, confirming that the transmitter is in a
Installation Manual
in place.
Figure 3-12: Removal of the sensor clamp
position.
You can rotate the transmitter to any of the eight positions, but a stop exists that
will not allow a full 360° rotation.
Figure 3-13: Rotate transmitter head
locked position.
Mounting and sensor wiring
October 2022
19