Emerson MicroMotion FOUNDATION 5700 Installation Manual page 17

Table of Contents

Advertisement

Installation Manual
MMI-20029969
4. Replace the transmitter-to-sensor wiring compartment cover and tighten the
Installation Manual
Figure 3-10: Four-wire transmitter-to-sensor wiring connections
Figure 3-11: Nine-wire transmitter-to-sensor wiring connections
Note
Connect the four drain wires in the nine-wire cable to the ground screw located
inside the junction box.
screws to 14 in lbf (1.58 N m) to 15 in lbf (1.69 N m).
Mounting and sensor wiring
October 2022
17