Rotate The Transmitter On The Sensor (Optional) - Emerson Micro Motion 5700 Installation Manual

With configurable outputs, all installation types integral, 4-wire, and 9-wire
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Installation Manual
MMI-20027478
3.5

Rotate the transmitter on the sensor (optional)

In integral installations, you can rotate the transmitter on the sensor up to 360º in 45º
increments.
Procedure
1. Using a 4 mm hex key, loosen and remove the clamp securing the transmitter head
2. Gently lift the transmitter straight up, and rotate the transmitter to the desired
3. Gently lower the transmitter onto the base, confirming that the transmitter is in a
Installation Manual
in place.
Figure 3-12: Removal of the sensor clamp
position.
You can rotate the transmitter to any of the eight positions, but a stop exists that
will not allow a full 360° rotation.
Figure 3-13: Rotation of the transmitter head
locked position.
Mounting and sensor wiring