Chapter 4: UEFI BIOS
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Enabled and Disabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between 1 to 255.
The default setting is 1.
METW (Multiple Event Count Time Window)
This feature is used to determine how long (in minutes) the multiple event counter should
wait before generating a new event log. Enter a number between 0 to 99. The default
setting is 60.
View System Event Log
This feature allows the user to view the event in the system event log. Select this feature
and press <Enter> to view the status of an event in the log. The following categories will
be displayed:
Date/Time/Error Code/Severity