10.2 TIG DC WELDING - SECOND LEVEL MENU

L5
L4
L7
L6
L8
L9
L13
L14
L15
3 sec ACTIVATION/
SELECTION
○ Hold down the S3
The LED will illuminate.
○ Use the encoder E1
A
The acronym relative to the selected setting is shown on display D1.
○ Press the S3
The value associated with the selected setting appears on display D1.
B
○ Using the encoder E1
Tab. 8 - Parameters of the 2nd level menu: DC TIG mode
ACRONYM / LED
SETTING
SP.t.
SPOT TIG TIME
HF
ENABLE HF ARC STRIKE
r.P.C.
MINIMUM PEDAL CURRENT
rC
REMOTE CONTROL ACTIVATION
Press any button
(except S3) to save the setting and quit the menu.
*1: The activation is suitable for the following welding modes:
• MMA
• DC TIG
Compatible remote control types:
• manual remote control.
• UP/DOWN or potentiometer TIG torch.
• foot pedal controller.
WELD THE WORLD
D1
L1
L2
L3
L12
Hf
L18
L19
L21
L17
L16
L20
S2
S3
A
button for 3 seconds to access the 2nd level menu.
to scroll the list of settings to be edited.
button to confirm.
to edit the value of the selected setting.
L10 L11
S1
E1
L25
L23
L22
L24
L26 L27
L29 L28
S4
S5
MIN
DEFAULT MAX
0.01 s 0.01 s
On
On
1 %
5 %
oFF
oFF
Cod. 006.0001.1420
08/09/2021 V.2.12
ENGLISH
B
SETTING
L30
L31
L32
L33
SYN
S6
NOTES
Only with 2 STROKE
10.0 s
SPOT
oFF
90 %
*2
On
*1
31