Weco Multi Power 204T Instruction Manual page 27

Table of Contents

Advertisement

Multi Power 204T
○ Press the S3
The value associated with the selected setting appears on display D1.
C
In this diagram the LED relative to the setting to be edited illuminates.
D
○ Using the encoder E1
(except S3) to save the setting and quit the menu.
Press any button
Tab. 6 - Parameters of the 1st level menu: CONTINUOUS DC TIG mode
ACRONYM / LED
SETTING
P.xx.
PRE-GAS TIME
L16
STARTING CURRENT
L17
UP SLOPE
WELDING CURRENT
L18
MAXIMUM CURRENT WITH RE-
MOTE CONTROLLER
L19
SECOND CURRENT B-LEVEL
L23
DOWN SLOPE
L24
FINAL CURRENT
L25
POST GAS TIME
Tab. 7 - Parameters of the 1st level Menu in TIG DC PULSED, TIG DC SYNERGIC PULSED mode.
ACRONYM / LED
SETTING
P.xx.
PRE-GAS TIME
L16
STARTING CURRENT
L17
UP SLOPE
WELD THE WORLD
button to scroll the list of settings to edit.
L18
L17
L16
, edit the value of the selected setting.
L18
L19
L17
L16
L18
L19
L17
L16
L19
L21
L25
L23
L20
L22
L24
L21
L25
L23
L20
L22
L24
MIN
DEFAULT MAX
0.0 s
0.1 s
9.9 s
5 A
40 A
200 A
2 %
50 %
200 %
0.0 s
0.0 s
25.0 s
5 A
80 A
200 A
10 %
50 %
200 %
0.0 s
0.0 s
25.0 s
5 A
5 A
170 A
5 %
5 %
80 %
0.0 s
10.0 s
25.0 s
L21
L25
L23
L20
L22
L24
MIN
DEFAULT MAX
0.0 s
0.1 s
9.9 s
5 A
40 A
200 A
2 %
50 %
200 %
0.0 s
0.0 s
25.0 s
Cod. 006.0001.1420
08/09/2021 V.2.12
ENGLISH
USEFUL ADVICE
Recommended value 0.3 s
* 2
* 2
Recommended value 0.1 s
* 1
Recommended value 0.5
* 2
* 2
* 3
USEFUL ADVICE
Recommended value 0.3 s
* 2
* 2
Recommended value 0.1 s
27