Cod. 006.0001.1420
08/09/2021 V.2.12
ENGLISH
D1
E1
S1
S2
S3
S4
S5
S6
12
WELD THE WORLD
Data setting: The display shows the acronym of the parameter to be set.
Welding: The display shows the effective amperes value during welding.
HOLD function: The display shows the average current value measured over the entire welding
period (excluding the starting and ending slopes).
Data setting: The encoder sets the value of the selected parameter.
Welding: The encoder sets the value of the following parameter: WELDING CURRENT
Parameters/functions setting: This button selects the parameter to be shown on the following
display: D1
Possible choices:
(A) Preset welding current
(V) No-load voltage
(EL) Preset type of electrode
Welding: This button selects the parameter to be shown on the following display: D1
Possible choices:
(A) Effective welding current
(V) Effective welding voltage
HOLD function: This button selects the parameter to be shown on the following display: D1
Possible choices:
(A) Average welding current
(V) Average welding voltage
TIG Mode: Press the button to select the parameter to be set.
:
Possible selections
Q-START, DYNAMIC ARC, MULTI TACK
MMA mode: DYNAMIC ARC
Press and release: the button selects the first level menu parameters.
Hold down for 3 seconds: the button opens the second level menu. When in the menu, press
and release the button to select the parameters.
Keep the button pressed while powering on the power source: the button opens the SETUP
menu.
Press and release: the button opens the JOBs upload menu.
Hold down for 3 seconds: the button opens the JOBs save and delete menu.
TIG DC / TIG AC mode: This button selects the torch trigger procedure.
MMA mode: Press the button to show the selected electrode type for MMA welding.
This button selects the welding mode.
Multi Power 204T

Advertisement

Table of Contents
loading

Table of Contents