u-blox LARA-R203 System Integration Manual page 80

Size-optimized lte cat 1 modules in single and multi-mode configurations
Table of Contents

Advertisement

2.2.1.10 Guidelines for removing VCC supply
As described in section 1.6.2 and Figure 15, the VCC supply can be removed after the end of LARA-R2 series
modules internal power-off sequence, which must be properly started sending the AT+CPWROFF command (see
the u-blox AT Commands Manual [2]).
Removing the VCC power can be useful in order to minimize the current consumption when the LARA-R2 series
modules are switched off. Afterwards, the modules can be switched on again by re-applying the VCC supply.
If the VCC supply is generated by a switching or an LDO regulator, the application processor may control the input
pin of the regulator which is provided to enable / disable the output of the regulator (as for example, the RUN
input pin for the regulator described in Figure 28, the INH input pin for the regulator described in Figure 29, the
SHDNn input pin for the regulator described in Figure 30, or the EN input pin for the regulator described in Figure
31), in order to apply / remove the VCC supply.
If the regulator that generates the VCC supply does not provide an on / off pin, or for other applications such as
the battery-powered ones, the VCC supply can be switched off using an appropriate external p-channel MOSFET
controlled by the application processor by means of a proper inverting transistor as shown in Figure 37, given that
the external p-channel MOSFET has provided:
Very low R
(for example, less than 50 m), to minimize voltage drops
DS(ON)
Adequate maximum Drain current (see the LARA-R2 series Data Sheet [1] for module consumption figures)
Low leakage current, to minimize the current consumption
VCC Supply Source
Application
GPIO
Processor
GND
Figure 37: Example of application circuit for a VCC supply removal
Reference
Description
R1
47 k Resistor 0402 5% 0.1 W
R2
10 k Resistor 0402 5% 0.1 W
R3
100 k Resistor 0402 5% 0.1 W
T1
P-Channel MOSFET Low On-Resistance
T2
NPN BJT Transistor
C1
330 µF Capacitor Tantalum D_SIZE 6.3 V 45 m
C2
10 nF Capacitor Ceramic X7R 0402 10% 16 V
C3
100 nF Capacitor Ceramic X7R 0402 10% 16 V
C4
56 pF Capacitor Ceramic C0G 0402 5% 25 V
C5
15 pF Capacitor Ceramic C0G 0402 5% 25 V
C6
8.2 pF Capacitor Ceramic C0G 0402 5% 50 V
Table 28: Components for a VCC supply removal application circuit
It is highly recommended to avoid an abrupt removal of the VCC supply during LARA-R2 series modules
normal operations: the power-off procedure must be started by the AT+CPWROFF command, waiting the
command response for a proper time period (see the u-blox AT Commands Manual [2]), and then a proper
VCC supply must be held at least until the end of the modules' internal power-off sequence, which occurs
when the generic digital interfaces supply output (V_INT) is switched off by the module.
UBX-16010573 - R12
T1
R3
+
R2
C1
T2
R1
LARA-R2 series - System Integration Manual
LARA-R2 series
51
52
53
C2
C3
C4
C5 C6
Part Number - Manufacturer
RC0402JR-0747KL - Yageo Phycomp
RC0402JR-0710KL - Yageo Phycomp
RC0402JR-07100KL - Yageo Phycomp
AO3415 - Alpha & Omega Semiconductor Inc.
BC847 - Infineon
T520D337M006ATE045 - KEMET
GRM155R71C103KA01 - Murata
GRM155R61A104KA01 - Murata
GRM1555C1E560JA01 - Murata
GRM1555C1E150JA01 - Murata
GRM1555C1H8R2DZ01 - Murata
VCC
VCC
VCC
GND