u-blox LARA-R203 System Integration Manual page 15

Size-optimized lte cat 1 modules in single and multi-mode configurations
Table of Contents

Advertisement

Function
Pin Name
USB_D+
HSIC
HSIC_DATA
HSIC_STRB
DDC
SCL
SDA
SDIO
SDIO_D0
SDIO_D1
SDIO_D2
SDIO_D3
SDIO_CLK
UBX-16010573 - R12
Pin No
I/O
Description
29
I/O
USB Data Line D+
99
I/O
HSIC USB data line
100
I/O
HSIC USB strobe
line
2
27
O
I
C bus clock line
2
26
I/O
I
C bus data line
47
I/O
SDIO serial data [0]
49
I/O
SDIO serial data [1]
44
I/O
SDIO serial data [2]
48
I/O
SDIO serial data [3]
45
O
SDIO serial clock
LARA-R2 series - System Integration Manual
Remarks
USB interface for AT commands, data communication, FOAT,
FW update by u-blox EasyFlash tool and diagnostic.
90  nominal differential impedance (Z
30  nominal common mode impedance (Z
Pull-up or pull-down resistors and external series resistors as
required by the USB 2.0 specifications [9] are part of the USB
pin driver and need not be provided externally.
If the USB interface is not used by the Application Processor,
Test-Point for diagnostic / FW update access is recommended
See section 1.9.2 for functional description.
See section 2.6.2 for external circuit design-in.
Not supported by "02" and "62" product versions.
USB High-Speed Inter-Chip compliant interface for AT
commands, data communication, FOAT, FW update by u-blox
EasyFlash tool and diagnostic.
50  nominal characteristic impedance.
Test-Point for diagnostic / FW update access is recommended.
See section 1.9.3 for functional description.
See section 2.6.3 for external circuit design-in.
Not supported by "02" and "62" product versions.
HSIC interface for AT commands, data communication, FOAT,
FW update by u-blox EasyFlash tool and diagnostic.
50  nominal characteristic impedance.
Test-Point for diagnostic / FW update access is recommended.
See section 1.9.3 for functional description.
See section 2.6.3 for external circuit design-in.
1.8 V open drain, for communication with I2C-slave devices.
See section 1.9.4 for functional description.
See section 2.6.4 for external circuit design-in.
1.8 V open drain, for communication with I2C-slave devices.
See section 1.9.4 for functional description.
See section 2.6.4 for external circuit design-in.
Not supported by "02" and "62" product versions.
SDIO interface for communication with u-blox Wi-Fi module
See section 1.9.5 for functional description.
See section 2.6.5 for external circuit design-in.
Not supported by "02" and "62" product versions.
SDIO interface for communication with u-blox Wi-Fi module
See section 1.9.5 for functional description.
See section 2.6.5 for external circuit design-in.
Not supported by "02" and "62" product versions.
SDIO interface for communication with u-blox Wi-Fi module
See section 1.9.5 for functional description.
See section 2.6.5 for external circuit design-in.
Not supported by "02" and "62" product versions.
SDIO interface for communication with u-blox Wi-Fi module
See section 1.9.5 for functional description.
See section 2.6.5 for external circuit design-in.
Not supported by "02" and "62" product versions.
SDIO interface for communication with u-blox Wi-Fi module
See section 1.9.5 for functional description.
See section 2.6.5 for external circuit design-in.
)
0
)
CM
System description
Page 15 of 157