Approval - Electrolux Professional IC6 48 FFS Series Installation Manual

Ironer
Hide thumbs Also See for IC6 48 FFS Series:
Table of Contents

Advertisement

50
3.6.3
D.E.S.P. approval
This technical form for pressure concerns an assembly constituted of :
- a cylinder classified in category of risk IV according to article 4 and Annex II of Directive 2014/68 / UE,
- pipings (DN20) responding to the article 4 point 3 of Directive 2014/68 /UE.
Manufacturer :
Electrolux Laundry System France SNC
52, Rue Pasteur
BP6
10430 Rosières-Près-Troyes
Technical data of the cylinder :
Maximum service pressure
Running temperature mini/maxi :
Volume of the equipment under pressure :
Pressure of test :
Pressure releasing of the device security
Anticipated usage :
Flatwork ironer
Volume of the equipement under
pressure (in dm3)
Installation manual
1000 kPa (10 bar)
15 °C / 184°C
see following table
1500 kPa (15 bar) at 20°C
1000 kPa (10 bar)
Steam heating
4819
300
4825
398
4832
497

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic6 4821 ffsIc6 4825 ffsIc6 4832 ffs

Table of Contents