If the gas inlet pressure (P1) is identical to the nominal pressure of the machine (P2), it is possible to insert a reser-
voir as close as possible to the machine in order to protect against any falls in pressure when the machine starts up.
Anfd increase the diameter of gas pipe supply to allow the flow rate.
3.7.2

Determinate the gas type :

Check with the customer the gas type that will be used to supply the machine. According this gas type the machine
must be set to corresponding to the gas type. For different gas that can be use with this ironer refer to appendices
chapter "Gas settings characteristics"
The gas pressure will be determinate by the gas type supply to the machine. According this pressure and gas type
the gas valve and injectors must be set in accordance to machine size.
Check appendices chapter "Gas settings characteristics" for complete information.
3.7.3

Gas valve setting

Machine was tested at the factory in natural gas.
If you are running natural gas check the valve is still in natural gas setting.
In case of other gas type the gas valve must be set.
Refers to appendices "Gas settings characteristics" for gas valve setting.
3.7.4

Injectors setting

Machine was tested at the factory in natural gas.
If you are running natural gas check the injectors are still in natural gas setting.
In case of other gas type the injectors must be set.
Refers to appendices "Gas settings characteristics" for injectors setting.