3.6 Steam and condensate connections :

There is always a risk that a certain amount of water will be carried in steam.
Water is carried in the lower parts of the supply tubes, and steam in the upper parts.
Make a swan neck branch-T on the main tube to prevent this water damaging the machine heating system. This will
ensure that only steam is retrieved without any condensed water.
A = Ironer
B = Line trap (supplied by the
customer)
C = Return of condensates
D = The valve is lockable in the
closed position ( supplied by the
customer)
E = Filter (supplied by the customer)
F = Steam trap (supplied by the
customer)
G = By-pass (needle valve) ( sup-
plied by the customer)
H = Non-return valve (supplied by
the customer)
M = Presssure gauge ( supplied by
the customer)
N = Thermal insulation for the pipe-
work (supplied by the customer)
S = Safety valve (supplied by the
customer)
V = Steam inlet