3.5.1

Fresh air inlet

To allow the dryer ironer to work at its best, it is important that the laundry air inlet passes through an opening from
the outside.
The fresh air arrival must be equivalent to the volume of evacuated air (please refer to the output of the fans at zero
pressure in the technical characteristics)
Important
In the case of several machines, these values should be added together.
In order to prevent drafts in the room, the best solution is to place the air inlet behind the machine.
In the case of a machine with gas heating, it is essential that the rooms should be ventilated.
The free section of the air inlet must be 5 times greater than the section of the evacuation pipe.
Do not forget to allow for the fact that grills often occupy half the total area of the free air opening.