36
3.4 Electrical connection
Prior to use, the machine should be plugged into a correctly earthed power socket complying with the standard in
force.
The mechanical and electrical installation of the machine should only be done by qualified personnel.
Make sure that both the power voltage is correct and the power supply of your installation is sufficient before con-
necting the machine.
Use only a cable to supply the machine.
The main switch is located on the rear side of the machine , identified by this sticker.
The use of power electronics (variator or filter for example) may lead to unexperted release of breakers with 30mA
differential current device.
To avoid these untimely activations, you ought to use differential protecting systems with residual current only, having
a high level of immunity as regards leakage transient current.
This type of breaker should thus be avoided, or a value of 300mA maximum should be observed according to stand-
ard NFC 15100.
For operation that will take place with power supply or/and machine power on, technicians who will operate must
have approval to work Low-voltage (1000V Ac max or 1500V DC) and use suitable safety equipment and tools.
To be in accordance with the Low-voltage authorization if the machine have the option electrostatics bar, this one
must be disconnect during technician operation, unless the technicians has a High-voltage authorization.
Installation manual
Important
Important
Caution