42
Before starting the machine, do not push the circuit breakers Q5 and Q701 in the electrical cabinet before
checking the fan's rotation direction.
For few seconds, manually activate the breaker that drive the fan motor :
Check on the electrical drawing for the breaker name. Then visually check the rotation way of the turbine. A sticker in-
dicate the correct rotation way. If the cheminey (B) is already connected, it is possible to check for the pipe (A).
On FFS ironer it is also necessary to check the correct way of belt into cross folding. To do so, it is possible to activate
few seconds the breaker that drive the cross motor. The belt must move in the correct direction. Check on the electri-
cal drawing for the breaker name. Then visually check the rotation way of the turbine.
If it is rotating in the wrong direction, invert two of the three phases on the power supply isolating switch to reverse
the direction of the rotation of the fan.
Check again the direction of the rotation of the fan then replace the hose and its collar.
The control geared unit for the ejection has a keyed transmission shaft and it is important that the direction of ro-
tation is correct, otherwise there is a danger that certain mechanical parts might suffer damage.
The verification of direction of rotation of the fan allows to eliminate this risk.
If the tests carried out on the various points mentioned above are satisfactory, the dryer ironer is ready for use.