Electrolux Professional IC6 48 FFS Series Installation Manual page 71

Ironer
Hide thumbs Also See for IC6 48 FFS Series:
Table of Contents

Advertisement

Installation manual
71
1 : Close the gas inlet and remove the binding screw from the pres-
sure tapping (F) and connect the manometer tube.
2 : The electricity supply must be energized otherwise gas will not be
supplied to the burner.
3 : Open and check the gas inlet main burner using the manometer on
the pressure tapping (F)
4 : Remove pressure regulator cap (D)
5 : Using a screwdriver , slowly turn the adjustment screw until the re-
quired pressure (P) is indicated on manometer ( see tables on follow-
ing pages).
Turn the adjustment screw clockwise to increase and counter-clock-
wise to decrease gas pressure.
6 : Reset the pressure regulator cap, close off the gas inlet, remove
the manometer tube and put the binding screw back in (F).