1 Door Preparation
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
Left Hand
Hinges Left.
Open Inward.
B. Door Preparation
Prepare door according to appropriate template.
If necessary, refer to website www.intelligentopenings.com
Prior to installation, make sure all holes are free of burrs, debris, and sharp edges.
If doors are not properly reinforced per ANSI 115.2, commercially available reinforcements
should be installed.
Templates:
• Manufacturer Template 4591
• Field Prep Template A7882
Raceway for ElectroLynx
Cable (12 Conductor)
From McKinney
Through-bolt
Holes (2 places)
Lock body Hole
A7884E • 800-810-WIRE (9473) • www.sargentlock.com
Left Hand
Reverse Bevel
Hinges Left.
"LH"
Open Outward.
"LHRB"
Outside of Door
Fig. 1B Wood Door Shown
Right Hand
Hinges Right.
Open Inward.
"RH"
Fig. 1A
Inside of Door
Latchbolt
Door Prep
Pre-drilled and/or
Tapped Holes (2 places)
8
Right Hand
Reverse Bevel
Hinges Right.
Open Outward.
"RHRB"
Raceway for ElectroLynx-
Cable (12 Conductor)
From McKinney
Hole for Cable (Reader
to Controller Board)
Pre-drilled and/or
Tapped Holes (2 places)
Through-bolt Holes (2 places)