MUTING+BLANKING (SH4-XX-XXXX-X models only)

It is possible to configure muting and blanking together with the following limitation: if
a Blanking Zone is configured for an object always present (Minimum Object > 0) all its
beams are excluded from muting. SH4 Designer does not allow to include those beams
inside Muting Zone.
If instead a Blanking Zone is configured for an object that can also be absent (Minimum
Object = 0) then its beams can be also muted.
86
SH4 ADVANCED
BLANKING ZONE 2
MUTING ZONE
BLANKING ZONE 1
MUTING ZONE
BLANKING ZONE 2:
Start beam: 8
End beam: 9
Object size min: 0
Object size max: 1 or 2
BLANKING ZONE 1:
Start beam: 3
End beam: 4
Object size min: 1 or 2
Object size max: 1 or 2