Datasensing SH4 ADVANCED Product Reference Manual page 35

Safety light curtains
Table of Contents

Advertisement

RECEIVER
DUAL CONNECTOR
RX M12 MALE 12 PIN
1 - 24V (brown)
2 - 0V (blue)
3 - GP_IN1 (white)
4 - GP_IN2 (green)
5 - OSSD2 (pink)
6 - GP_IN3 (yellow)
7 - GP_IN4 (black)
8 - OSSD1 (grey)
9 - OVR2 (red)
10 - GP_IO1 (violet)
3
11 - GP_IO2 (grey-pink)
12 - NOT CONNECTED (red-blue)
RX M12 FEMALE 5 PIN
1 - 24V OUT (brown)
2 - GP_IN5 (white)
3 - 0V OUT (blue)
4 - GP_IN6 (black)
4
5 - GP_IO2 (grey)
1. Pin 2-2 of male-female connector are internally short-circuited thus should be connected one-
side only
2. Pin 4-4 of male-female connector are internally short-circuited thus should be connected one-
side only
3. Must be left floating when used as cascade master
4. Internally short-circuited with Pin 11 of main connector
NOTE: For all body models only (SH4-X-XXXX-X), pin 2 of the emitter (TX)
connector is also used for the Emission Range Selection function, refer to
"Emission Range Selection (SH4-X-XXXX-X models only)" on page 63.
ELECTRICAL CONNECTION
EMITTER
DUAL CONNECTOR
TX M12 MALE 5 PIN
1 - 24V (brown)
2 - TEST/(AIMER) (white)
3 - 0V (blue)
2
4 - CODE (black)
5 - COM (grey)
TX M12 FEMALE 5 PIN
1 - 24V OUT (brown)
2 - TEST/(AIMER) (white)
3 - 0V OUT (blue)
4 - CODE (black)
5 - CASCOM (grey)
PRODUCT REFERENCE GUIDE
1
27

Advertisement