Auto-Dynamic Partial Muting - Datasensing SH4 ADVANCED Product Reference Manual

Safety light curtains
Table of Contents

Advertisement

Auto-Dynamic Partial Muting

Auto-Dynamic Partial Muting automatically configures a muting zone when muting is
active and after moving goods has intercepted the light curtain for 2 seconds (configu-
rable).
Muting starts with full detection zone muted, then is restricted to the maximum num-
ber of beams intercepted during the first 2 seconds of goods blocking the light curtain.
A tolerance Ht may be set to allow irregular shaped goods.
Partial Muting Zone can be set to start from top beam if light curtain is upside-down
mounted.
Auto-Dynamic Partial Muting is independent from sensors configuration so it can be
activated with all muting types.
MUTING STATE
PARAMETER
Dynamic Muting
Figure 50: Auto Dynamic Partial Muting
MUTING1
MUTING2
ESPE
Figure 51: Auto Dynamic Partial Muting Timings
DESCRIPTION
Teach time (ms): time after which muting is partia-
lized to maximum detected material height
Beam Tolerance: additional intercepted beams
allowed over maximum taught height
Start form top: use if light curtain is installed up-side
down
All zone
Partial zone
Teach time
ON
OFF
FREE
INTERCEPTED
VALUE [DEFAULT]
500 to 4000 [2000]
Beam tolerance: 0 to 6 [0]
Only for SH4-XX-XXXX-X models.
Start from top: yes/no [no]