Configuration - Datasensing SH4 ADVANCED Product Reference Manual

Safety light curtains
Table of Contents

Advertisement

FUNCTIONS
When object size is less than zone size it can move freely inside the blanking zone.
When minimum size is 0 it means that the object size is less than the optical resolution
or the object can be removed from the blanking zone.
In figure below three examples are provided with different blanking zone parameters.
Where blanking zone is represented in red color, OSSDs are LOW because of objects not
matching blanking settings.
BZ
Start beam: 2
End beam: 5
Zone size: 4
Object size min: 1
Object size max: 2
BZ
Start beam: 2
End beam: 5
Zone size: 4
Object size min: 4
Object size max: 4
BZ
Start beam: 3
End beam: 5
Zone size: 3
Object size min: 0
Object size max: 2

Configuration:

1. In "Configuration" tab, choose "Advanced Functions"
2. In the "Advanced Functions" window choose "Blanking" by clicking on the
82
SH4 ADVANCED
BZ
BZ
BZ
Figure 62: Blanking zones examples
"Advanced Functions" box.
1
BZ
BZ
BZ
BZ
BZ
BZ
2
BZ
BZ
BZ
BZ
BZ

Advertisement

Table of Contents
loading

Table of Contents