Pairing table
SH4-2/3/4-XXXX-A-12-5
RESPONSE TIMES
Next tables resumes the response time values of every SH4 models related to the num-
ber of beams and the protected height.
The response time is a function of the protected height, the resolution of the light cur-
tain and Anti Interference Coding (AIC) selection.
SH4-14-XXXX-X-X models
SH4-14-0300-x-x
SH4-14-0450-x-x
SH4-14-0600-x-x
SH4-14-0750-x-x
SH4-14-0900-x-x
SH4-14-1050-x-x
SH4-14-1200-x-x
SH4-14-1350-x-x
SH4-14-1500-x-x
SH4-14-1650-x-x
SH4-14-1800-x-x
SH4-14-1950-x-x
SH4-14-2100-x-x
SH4-14-2250-x-x
SH4-30-XXXX-X-X models
SH4-30-0300-x-x
SH4-30-0450-x-x
SH4-30-0600-x-x
SH4-30-0750-x-x
SH4-30-0900-x-x
SH4-30-1050-x-x
SH4-30-1200-x-x
SH4-30-1350-x-x
PAIR MODEL
SH4-14-XXXX-A-12
SH4-14-XXXX-A-12-5
SH4-30-XXXX-A-12
SH4-30-XXXX-A-12-5
PROTECTED
MODEL
HEIGHT (mm)
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
CONTROLLED
MODEL
HEIGHT (mm)
300
450
600
750
900
1050
1200
1350
RECEIVER MODEL
SH4-14-XXXX-A-R-12
SH4-14-XXXX-A-R-12-5
SH4-30-XXXX-A-R-12
SH4-30-XXXX-A-R-12-5
SH4-2/3/4-XXXX-A-R-12-5
RESPONSE TIME
NO. BEAMS
AIC DISABLE
30
45
60
75
90
105
120
135
150
165
180
195
210
225
RESPONSE TIME
NO. BEAMS
AIC DISABLE
12
18
24
30
36
42
48
54
RESPONSE TIMES
EMITTER MODEL
SH4-14-XXXX-TP-5
SH4-14-XXXX-TP-5-5
SH4-30-XXXX-TP-5
SH4-30-XXXX-TP-5-5
SH4-2/3/4-XXXX-TP-5-5
RESPONSE TIME
(ms)
(ms)
AIC ENABLE
9
14
10
18
12
22
13
26
15
30
16
33
18
37
20
41
21
45
23
49
24
52
26
56
27
60
29
64
RESPONSE TIME
(ms)
(ms)
AIC ENABLE
7
10
8
12
9
13
9
15
10
17
11
18
12
20
12
22
PRODUCT REFERENCE GUIDE