Datasensing SH4 ADVANCED Product Reference Manual page 78

Safety light curtains
Table of Contents

Advertisement

FUNCTIONS
PARAMETER
T
Min Selection (ms)
12
T
Max Selection (s)
12
T Delay (ms)
Timeout (s)
Infinite Timeout
Muting Deactivation Filter (ms)
Muting Activation Filter (ms)
Dynamic Muting
Muting Lamp Integrity Check
Override Mode Selection
Override Timeout (min)
Override Restart
(when the Manual Restart is selected)
70
SH4 ADVANCED
DESCRIPTION
Minimum time between muting signals
Maximum time between muting signals
Additional muting time at the end of muting sequence 0 to 1000 [0]
Maximum muting duration
Unlimited muting duration
Filter on muting signals deactivation
Filter on muting signals activation
Teach time (ms): time after which muting is partia-
lized to maximum detected material height
Beam Tolerance: additional intercepted beams
allowed over maximum taught height
Start form top: use if light curtain is installed up-side
down
Checks for presence and integrity of external lamp
Level trigger: override signals must remain active for
all override sequence
Edge trigger: override signals are not required to
remain active for all override sequence
Maximum override duration
Auto
Manual
VALUE [DEFAULT]
50 to 1000 [100] for SH4-XX-XXXX-X-X
10 to 1000 [100] for SH4-X-XXXX-X-X
1 to 16 [4]
10 - 57600 [10 min]
yes/no [no]
0 to 1000 [0]
0 to 1000 [0]
500 to 4000 [2000]
Beam tolerance: 0 to 6 [0]
Only for SH4-XX-XXXX-X models.
Start from top: yes/no [no]
yes/no [no]
1 to 256 [2]
At the end of the Override the ESPE
remains with the outputs high and
monitors if any intrusions occur.
At the end of the Override, the ESPE
goes into Interlock state and waits for
a manual restart signal.