REDUCED RESOLUTION (SH4-XX-XXXX-X models only)

Reduced resolution can be used if Blanking is not configured. A reduced resolution can
be set to allow objects smaller than a certain size to interrupt the light curtain without
triggering safety function.
REDUCED
RESOLUTION
SETTING
MINIMUM
CONTIGUOUS BEAMS
THAT WILL TRIGGER
SAFETY FUNCTION
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
NOTE: Effective resolution can be calculated as:
For 14 mm = 14 + (max size - min size)*10
For 30 mm = 30 + (max size - min size)*25
REDUCED RESOLUTION (SH4-XX-XXXX-X MODELS ONLY)
DETECTION
CAPABILITY (FOR
SH4-14-*) IN mm
14
24
34
44
54
64
74
84
94
104
114
PRODUCT REFERENCE GUIDE
DETECTION
CAPABILITY (FOR
SH4-30-*) IN mm
30
55
80
105
130
155
n/a
n/a
n/a
n/a
n/a
85