6 Diagnosis/visualisation X4A
ACHTUNG
6.1 Assignment of the terminal strip X4A
6.2 Data cable RS232 PC-Drive Controller
ma_dr_f6-cu-p-inst-20182705_en
The integrated serial interface provides the following functions:
• Parameterization of the device with the KEB software COMBIVIS.
• Connection of a control operator.
• DIN66019II as communication protocol.
Interface
RS485
RS232
Tab. 11: Serial interfaces
Name
RS232 PC inverter (SubD-9 coupling -
SubD-9 plug)
RS232/USB (USB serial converter in-
clusive cable)
Tab. 12: Connecting cable
No potential separation of the diagnostic interface to the control voltage!
Malfunction or defect caused by voltage differences.
a) Install equipotential bonding conductor if voltage differences > common-mode
signal.
XML file required for COMBIVIS 6.
a) A current XML file is required for the operation with COMBIVIS 6.
b) The download can be done directly from COMBIVIS 6 while an Internet con-
nection is present.
Abb. 1: Pin assignment socket D-Sub-9 (top view)
1 reserved
3 RxD (RS232)
5 RxD-B (RS485)
7 DGND (reference potential)
9 TxD-B (RS485)
1
6
9
5
Abb. 2: Serial cable for the connection to a PC

Diagnosis/visualisation X4A | 6

Specification
Common-mode voltage range 0...12 V
ANSI TIA/EIA-232
Material number
0058025-001D
0058060-0040
5 4 3 2 1
1
5
4
2
3
9
8
7
6
9 8 7 6
2 TxD (RS232)
4 RxD-A (RS485)
6 reserved
8 TxD-A (RS485)
0058025-001D
5
9
6
1
27