9.2.1 Operation without temperature detection
9.2.2 Connection of a KTY sensor
ACHTUNG
Settings KTY input
Connection KTY sensor
9.2.3 Connection of PTC, temperature switch or PT1000
Settings of PTC, temperature
switch or PT1000
Connection
ma_dr_f6-cu-p-inst-20182705_en
Brake control and temperature detection | 9
Operating mode (dr33)
4
PT1000
-
Monitoring
Use of the COMBIVERT without evaluation of the temperature input:
Switch off evaluation (pn12 =7) or install bridge between terminal TA1 (X1C.9) and
TA2 (X1C.10) (dr33=1).
No protection of the motor winding in case of wrong connection!
Non-observance leads to incorrect measurements and possibly to the de-
struction of the motor winding
a) Operate KTY sensors in forward direction.
b) KTY sensors may not be combined with other detections.
Setting
dr33 = 0 => KTY84/130
dr33 = 3 => KTY83/110
KTY84
Stetting
dr33 = 1 => PTC or temperature switch
dr33 = 4 => PT1000
Thermal contact (NC contact)
Temperature sensor (PTC) or PT1000
Resistance
1 kΩ
1.38 kΩ
1.75 kΩ
<0.04 kΩ
> 79.5 kΩ
TA1
+
TA2
Temperature/state
0 °C
100 °C
200 °C
Short circuit
No connection
(sensor break)
TA1
TA2
TA1
TA2