7 Fieldbus interfaces
7.1 Type code fieldbus
7.2 CAN
Specification
Connection
120Ω
Abb. 3: Connection CAN bus
NET ST - LED in CAN mode
Light pattern NET ST LED (red/
green combination)
ma_dr_f6-cu-p-inst-20182705_en
A CAN interface is integrated in the control unit as standard. Other fieldbus inter-
faces are identified by the 10th digit of the material number.
10. digit
Control board variant
3
PRO | Multi encoder interface, CAN®, Ethernet fieldbus interface, RS485
potential-free
4
PRO | no encoder interface, CAN®, Ethernet fieldbus interface, safe relay
5
PRO | Multi encoder interface, CAN®, Ethernet fieldbus interface, safe re-
lay
Fieldbus type
Transmission level
Transmission speed
Potential separation
Bus termination
X2A.23
CAN_L
X2A.24
CAN_H
X2A.25
CAN_GND
Clamp Name
X2A.23 CAN low
X2A.24 CAN high
X2A.25 CAN GND
According to CiA 303-3, the NET ST LED is a combination of RUN and ERROR
LED.
Status
Pre-Op
Stop

Fieldbus interfaces | 7

CAN

According to DIN ISO 11898; ISO High
Speed
20, 25, 50, 100, 125, 250, 500, 1000
kbit/s; adjustable via (fb66)
Functional insulation between CAN ter-
minals and to the control potential.
120 Ω external between (CAN High and
CAN Low) at both ends of the bus line.
CAN_L
CAN_H
CAN_GND
Note
No internal bus termination
CAN ground (can be wired depending on the cus-
tomer subscriber)
Light pattern
g-0 (grid 200 ms)
g-0-0-0-0-0 (grid 200 ms)
120Ω
Description
Device in PRE-OPERA-
TIONAL status
Device in STOPPED
status