5. Adjust both left and right horizontal adjusters by half the number of turns, in the opposite
direction of the vertical adjust.
For example, if the vertical adjust cap screw was turned 1/8 of a turn, the left and right
horizontal cap screws should be turned 1/16 of a turn in the opposite direction.
6. Check the screen each time an adjustment is made.
If the quality of the projected image has degraded, turn the vertical adjust screw 1/8 of a turn
clockwise.
Make sure the left and right horizontal adjusters are adjusted equally in the opposite direction
to correct axial focus. The 1/8 of a turn is a suggestion only and can be less if needed;
however, never exceed it. Always compensate both left and right horizontal adjustments
according to the vertical adjustment.
7. Check the image after each adjustment.
8. Continue to make adjustments until both the top and bottom are equally sharp.
To make sure the lens is in the same relative position, adjust the left and right horizontal
adjusters in the opposite direction at the same time.
9. When the top and bottom of the image are equally in focus tighten the lock screw to hold it in
position.
10. Recheck the image.
11. If additional adjustment is required, try adjusting horizontal boresight.
12. Replace the lens surround.