REMKO Smart-Control Touch
7
Error messages on the Smart Control
Operating messages, warnings and error display on the Smart-Control
Operating messages
ID
Description
Storage tank 1: Max.
ID6000
temperature reached
ID6001 HW request
Heat pump compressor
ID6002
start
Switching cycle disa-
ID6003
bled (I/O2)
Low pressure differ-
ID6004
ence
ID6005 Internal pump lead time
Switching cycle disa-
ID6006
bled
ID6007 Min. holding time
ID6008 Disable signal
ID6009 Disable signal (I/O 2)
Heat pump compressor
ID6010
start (I/O 2)
Maximum defrosting
ID6011
period
ID6012 Defrosting HP (I/O 2)
Pump internal
ID6020
after-run time
ID6022 Min. holding time (I/O2)
Maintenance 1 year
ID6100
interval
ID6103 Heat demand HP
ID6104 Cooling demand HP
ID6105 Defrost heat pump
ID6107 Standby mode active
Random delay after
ID6108
power failure
Outdoor temp. Heat
ID6109
pump usable limit
92
Desig. Details
The temperature on one of the probes in storage tank 1 is
higher than the maximum permitted storage tank temperature
There is an active requirement to charge the storage tank
Heat pump compressor start
The heat pump was disabled in order to reduce the compres-
sor's switching cycles
µPC2
The pressure difference is too low
The internal pump runs at reduced speed during the pump
lead time
The heat pump was disabled in order to reduce the compres-
sor's switching cycles
The heat pump is disabled due to a min. holding time
S16
The heat pump is disabled due to a disable signal
The heat pump is disabled due to a disable signal
Heat pump compressor start
µPC2
Maximum defrosting period
Defrost heat pump
The internal pump runs at a reduced speed during the pump
after-run time
The heat pump is disabled due to a min. holding time
Check solar circuit medium
Heat demand, heat pump
Cooling demand, heat pump
Defrost heat pump
Standby mode active
Random delay after power failure (up to 200 seconds after
power returns) - the purpose of the random delay is to avoid a
system overload due to many consumers being switched on at
the same time
Outdoor temp. Heat pump usable limit - the heat pump is disa-
bled due to the usable limits being exceeded or not being
reached
Need help?