Emergency-Heat Operation - REMKO Smart Control Touch Operating Manual

For the wsp heat pump range
Hide thumbs Also See for Smart Control Touch:
Table of Contents

Advertisement

REMKO Smart-Control Touch

4.5 Emergency-heat operation

To activate Emergency-heat operation, the param-
eter "Heat pump" must be changed from "acti-
vated" to "deactivated". This is only possible at the
expert level. To do so, touch the REMKO logo in
the upper right corner of the display.
After activating the expert level by touching the
corresponding REMKO logo, a password is
required. To enter the password at this level, use
"+/-" and then proceed to the next item with "Next".
Once you have finished entering the REMKO
default password "0321", confirm the input with
"OK".
Now the expert level is enabled.
Overview (user)
Touch the REMKO logo
Enter Expert password
Overview (expert)
In the expert level, the parameter "Heat pump" can
be accessed as follows:
Overview (expert)
Settings
Default settings
System configuration
Heat pump (activated)
36
¯
¯
¯
¯
¯
¯
¯
Then deactivate the heat pump by touching the
parameter "Heat pump" and changing from "acti-
vated" to "deactivated" via the indicators "V and Λ".
Then confirm the change with "OK".
System configuration
Touch "Heat pump activated"
Heat pump deactivated
With the deactivation of the heat pump, the Emer-
gency-heat operation via the auxiliary heating is
active.
To return to the basic display, touch the REMKO
logo.
From software version 4.28 it is possible to
save the emergency-heat operation as a widget
in the start menu. You will find a description of
this in the chapter "Operation - General infor-
mation".
¯
¯