Table C-2. LTO Tape Drive Sense Data (continued)
Byte
7
12–13
Additional Sense Code (ASC) —
Additional Sense Code Qualifier (ASCQ) (Continued)
Byte 12
Byte 13
ASC
ASCQ
2A
01 - Mode Parameters Changed — The Mode parameters for the drive have
2C
00 - Command Sequence Error
2F
00 - Commands Cleared by Another Initiator
30
00 - Incompatible Media Installed — A write type operation could not be
30
01 - Unknown Format — An operation could not be carried out because the cartridge
30
02 - Incompatible Format — An operation could not be completed because the
30
03 - Cleaning Cartridge Installed — An operation could not be carried out
30
05 - Cannot Write Medium, Incompatible Format
30
07 - Cleaning Failure — A cleaning operation was attempted, but could not
31
00 - Media format corrupted — Data could not be read because the format on tape is
37
00 - Rounded parameter — A Mode Select command parameter has been
3A
00 - Media Not Present — A media access command has been received
3B
00 - Sequential Positioning Error — A command has failed and left the logical
3B
0C - Position Past Beginning of Medium — A command that required the medium
3D
00 - Invalid bits in identify Message — An illegal Identify Message has been
3E
00 - Logical Unit has not Self-Configured — The drive has just powered on and
3F
01 - Code Download — The firmware in the drive has just been changed
3F
03 - Inquiry Data has Changed
3F
0E - Reported LUNs Data has Changed
3F
0F - Echo Buffer Overwritten
40
xx - Diagnostic failure — A diagnostic test has failed. The xx (ASCQ) is a
41
00 - Data Path Failure
43
00 - Message Error — A message could not be sent or received due to excessive
44
00 - Internal target failure — A hardware failure has been detected in the drive
45
00 - Select/Reset Failure — An attempt to reselect an initiator in order to
48
00 - Initiator Detected Error Message Received
49
00 - Invalid Message Error
4A
00 - Command Phase Error
4B
00 - Data Phase Error — A command could not be completed because too many
4E
00 - Overlapped Commands — An initiator selected the drive even though it
(Continued on next page)
C-10
TS3310 Tape Library Setup and Operator Guide
6
5
been changed by an initiator other than the one issuing the command
executed because it is not supported on the cartridge type that is loaded.
in the drive is of a format not supported by the drive
Logical Format is not correct
because the cartridge in the drive is a cleaning cartridge
be completed for some reason
not valid, but is a known format. A failure occurred attempting to write the FID
rounded because the drive can not store it with the accuracy of the command.
when there is no cartridge loaded
position at an unexpected location
to be at BOP was attempted when the medium was not at BOP
(e.g., Set Capacity)
received at the drive at the start of a command
has not completed its self test sequence and can not process commands
by a Write Buffer command
vendor specific code indicating the failing component.
transmission errors
that has caused the command to fail
complete the command has failed
parity errors occurred during the Data phase
already had a command outstanding in the drive
Bit Address or Name
4
3
2
1
0