Table C-1. Library Sense Data and associated ASC/ASCQs (continued)
Sense
Key
ASC
ASCQ
B
08h
86h
B
08h
87h
B
08h
88h
B
08h
B0h
B
08h
B1h
B
08h
B2h
B
08h
B3h
B
08h
B4h
B
08h
B5h
B
08h
B6h
B
08h
B7h
4
15h
01h
5
1Ah
00h
B
1Bh
00h
5
20h
00h
5
21h
01h
Description
LU Communication - SCSI Aborted
LU Communication - SCSI Abort Failed
LU Communication - SCSI Status Failed
LU Communication - FC Data Underrun
LU Communication - FC DMA Error
LU Communication - FC Reset
LU Communication - FC Data Overrun
LU Communication - FC Queue Full
LU Communication - Port Unavailable
LU Communication - Port Logged Out
LU Communication - Port Configuration
Changed
A mechanical positioning error occurred.
Parameter list length error.
Synchronous data transfer error
Illegal opcode in CDB
Invalid element address in CDB
Required Action
**Ask the customer to try the job using a
different tape cartridge. If the problem
persists, see if updated drive code is
available. If newer code is available, install
it.
Failure Isolation Procedure
CRU/FRU List
1. If the problem persists, select Tools →
Service and run the Robotics Test.
2. If the problem persists, contact your next
level of support.
Wrong or invalid firmware values.
Failure Isolation Procedure
See "Contacting IBM Technical Support" on
page 9-15.
Failure Isolation Procedure
Review host error data to determine which
control path drive reported the error, then
isolate and repair the failing SCSI or Fibre
Channel component.
Invalid Command Operation Code in CDB.
The Operation Code specified in the
Command Descriptor Block was not valid.
Failure Isolation Procedure
See "Contacting IBM Technical Support" on
page 9-15.
Wrong or invalid firmware values.
Failure Isolation Procedure
See "Contacting IBM Technical Support" on
page 9-15.
Appendix C. Sense Data