Table C-1. Library Sense Data and associated ASC/ASCQs (continued)
Sense
Key
ASC
ASCQ
2
04h
01h
2
04h
03h
2
04h
83h
2
04h
8Dh
B
08h
80h
B
08h
82h
B
08h
83h
B
08h
84h
B
08h
85h
C-2
TS3310 Tape Library Setup and Operator Guide
Description
The library is becoming ready.
The library is not ready and a manual
intervention is required.
The library is not ready due to aisle
power being disabled.
The library is not ready, because it is
offline.
LU Communication - SCSI Failure
LU Communication - SCSI Command
Execution or Queuing Failure
LU - SCSI Command Failed
LU Communication - SCSI Time-Out
LU Communication - SCSI Autosense
Failed
Required Action
Not Ready - Becoming Ready.
The drive has not finished the load and
thread operation yet.
Failure Isolation Procedure
No repair action required.
**Not Ready - Manual Intervention
Required.
Failure Isolation Procedure
Check the library Operator Panel to ensure
that the library is not in offline, setup, or
maintenance mode. Check front doors to
ensure that they are all closed. Ensure that
power is on each of the installed drives.
Possible failure of a door switch.
FRU/CRU List
See "Contacting IBM Technical Support" on
page 9-15.
**Not Ready - Library Has Not Been Set
Up.
Library needs configuration and/or
calibration.
Check the Spooler Cable connection.
Failure Isolation Procedure
Have your customer run Library
Configuration (select Reports->Library
Configuration)
FRU/CRU List
See "Contacting IBM Technical Support" on
page 9-15.
**Library is Offline.
Failure Isolation Procedure
Check the library Operator Panel to ensure
that the library is not in offline, setup, or
maintenance mode.